Ohm's law and circuit numericals, without the confusion
Series and parallel resistance, how to set out a numerical so it earns full marks, and why the same current does not flow everywhere.
What Ohm's law says
At a constant temperature, the current through a conductor is directly proportional to the potential difference across it.
V = IR
where V is in volts, I in amperes and R in ohms. The condition matters: Ohm's law holds at constant temperature. A filament bulb gets hot as current rises, its resistance changes, and its V–I graph curves. That is why a bulb is called a non-ohmic conductor, and it is a favourite one-mark question.
For an ohmic conductor, a graph of V against I is a straight line through the origin, and its slope is the resistance.
What decides resistance
R = ρl / A
Resistance goes up with length and down with cross-sectional area. The constant ρ is resistivity, a property of the material itself. A thick short wire has low resistance; a thin long wire has high resistance. That is why connecting wires are thick and heating elements are long and thin.
Series and parallel
In series the components sit one after another on a single path.
- The same current flows through every component.
- The voltages add: V = V₁ + V₂ + V₃
- Total resistance: R = R₁ + R₂ + R₃
In parallel the components sit on separate branches between the same two points.
- The voltage across each branch is the same.
- The currents add: I = I₁ + I₂ + I₃
- Total resistance: 1/R = 1/R₁ + 1/R₂ + 1/R₃
Two useful checks. In series, the total resistance is always larger than the largest resistor. In parallel, it is always smaller than the smallest one. If your answer breaks either rule, you have made an arithmetic slip — and noticing takes five seconds.
Notice the smaller resistor carries the larger current. Current takes the easier path — though not only the easier path, which is a common misconception.
Power and heating
Three forms of the same equation, and the trick is choosing the convenient one:
P = VI = I²R = V²/R
Use P = I²R when you know the current, and P = V²/R when you know the voltage. Energy is then E = Pt, and the commercial unit is the kilowatt-hour: 1 kWh = 3.6 × 10⁶ J.
Setting out a numerical for full marks
Examiners award method marks, so show the method even when you can do it in your head.
- Write down what you are given, with units. "V = 12 V, R₁ = 6 Ω, R₂ = 3 Ω."
- Write the formula before substituting. The formula itself earns a mark.
- Substitute with units, then compute.
- State the answer with its unit, and box it.
An answer of "6" with no unit is not a current. It may lose the final mark even when the working is right.
Show answer
Parallel section: 1/R = 1/5 + 1/10 + 1/30
Take the LCM, 30: 1/R = 6/30 + 3/30 + 1/30 = 10/30 = 1/3, so R = 3 Ω.
Check: 3 Ω is less than 5 Ω, the smallest. Good.
Total circuit resistance: 3 + 2 = 5 Ω
Current: I = V/R = 6/5 = 1.2 A
The mistakes that come up every year
Adding parallel resistances directly. 1/R = 1/R₁ + 1/R₂ gives you the reciprocal. Having found 1/R = 1/2, you must still flip it to get R = 2 Ω. Stopping at 1/2 is the single most common error in this chapter.
Assuming the same current everywhere in a parallel circuit. The voltage is shared, the current is not.
Mixing up a domestic circuit. In a house, appliances are wired in parallel, so each gets the full 220 V and each can be switched independently. Questions ask why — that is the answer.
Forgetting to convert. Milliamperes to amperes, kilowatt-hours to joules, minutes to seconds. Do the conversion in the "given" list at the top, before any calculation.
Stuck on this in your own textbook?
Ask our tutor about this chapter and get an answer drawn from the book your board actually prescribes, with the passage cited.
Try a lesson free